{"id":515,"date":"2017-12-17T19:22:54","date_gmt":"2017-12-17T08:22:54","guid":{"rendered":"http:\/\/furzy.com\/mikesblog\/?p=515"},"modified":"2018-04-30T21:52:12","modified_gmt":"2018-04-30T11:52:12","slug":"din001-stm32f091rc-iso485-io-new-controller-product","status":"publish","type":"post","link":"http:\/\/furzy.com\/mikesblog\/2017\/12\/17\/din001-stm32f091rc-iso485-io-new-controller-product\/","title":{"rendered":"DIN001 STM32F091RC ISO485 IO &#8211; New Controller Product"},"content":{"rendered":"<div id=\"attachment_514\" style=\"width: 650px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2017\/12\/DIN001-STM32F091RC-ISO485-IO-_640x523.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-514\" class=\"size-full wp-image-514\" src=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2017\/12\/DIN001-STM32F091RC-ISO485-IO-_640x523.jpg\" alt=\"DIN001 STM32F091RC ISO485 IO Controller\" width=\"640\" height=\"523\" srcset=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2017\/12\/DIN001-STM32F091RC-ISO485-IO-_640x523.jpg 640w, http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2017\/12\/DIN001-STM32F091RC-ISO485-IO-_640x523-300x245.jpg 300w, http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2017\/12\/DIN001-STM32F091RC-ISO485-IO-_640x523-367x300.jpg 367w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/a><p id=\"caption-attachment-514\" class=\"wp-caption-text\">DIN001 STM32F091RC ISO485 IO Controller &#8211; This first PCB from PCBWAY loaded by hand<\/p><\/div>\n<p>Applications<\/p>\n<ul>\n<li>Distributed Control Systems<\/li>\n<li>RS485 Networked Systems<\/li>\n<li>HVAC<\/li>\n<\/ul>\n<p>On Board<\/p>\n<ul>\n<li>2 x ADM2687 isolated RS485 transcievers<\/li>\n<li>1 x non isolated RS485 port<\/li>\n<li>4 Analog Inputs<\/li>\n<li>Opto Mosfet Output<\/li>\n<li>Isolated Analog Control Port for Fans<\/li>\n<li>Local Power Management (for a 48V Backbone Network Power Supply)<\/li>\n<li>Local 24V Supply for Sensors<\/li>\n<li>STM32F091RC<\/li>\n<li>SPI Flash for Logging and Settings MX25R8035 (1 MByte)<\/li>\n<\/ul>\n<p>Fits a SZOMK DIN Enclosure AK-DR-04 (6 unit &#8211; 108mm wide).<br \/>\nInstall with a Meanwell HDR-15-48, fits Electrical Distribution Enclosures.<\/p>\n<p><strong>This distributed control product will be offered for manufacture under license &#8211; contact us for further details.<\/strong><\/p>\n<p>We are looking for Car Park Ventilation FAN manufacturers interested in having their FAN driver in our firmware, please do not hesitate to contact us.<\/p>\n<p>A short video showing our DIN001 with some ventilation FANs.<\/p>\n<table style=\"border: none; width: auto;\">\n<tbody>\n<tr>\n<td style=\"border: none; padding: 0;\">\n<span class=\"embed-youtube\" style=\"text-align:center; display: block;\"><iframe loading=\"lazy\" class=\"youtube-player\" width=\"584\" height=\"329\" src=\"https:\/\/www.youtube.com\/embed\/s74mvP8qTVY?version=3&#038;rel=1&#038;showsearch=0&#038;showinfo=1&#038;iv_load_policy=1&#038;fs=1&#038;hl=en-US&#038;autohide=2&#038;wmode=transparent\" allowfullscreen=\"true\" style=\"border:0;\" sandbox=\"allow-scripts allow-same-origin allow-popups allow-presentation allow-popups-to-escape-sandbox\"><\/iframe><\/span><br \/>\n<iframe loading=\"lazy\" title=\"20180124 DIN001 Fan Interface Testing at REGA _MVI 3626\" width=\"584\" height=\"329\" src=\"https:\/\/www.youtube.com\/embed\/OdTDyWvRO3U?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Please contact us if interested in updates on this product.<\/p>\n<div id=\"attachment_672\" style=\"width: 650px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2018\/02\/DIN001-STM32F091RC-ISO485-IO-_Encl_PCB-_640x286.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-672\" class=\"size-full wp-image-672\" src=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2018\/02\/DIN001-STM32F091RC-ISO485-IO-_Encl_PCB-_640x286.jpg\" alt=\"DIN001 Distributed Controller - BMS \/ HVAC \/ IO - Fan Interface\" width=\"640\" height=\"286\" srcset=\"http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2018\/02\/DIN001-STM32F091RC-ISO485-IO-_Encl_PCB-_640x286.jpg 640w, http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2018\/02\/DIN001-STM32F091RC-ISO485-IO-_Encl_PCB-_640x286-300x134.jpg 300w, http:\/\/furzy.com\/mikesblog\/wp-content\/uploads\/2018\/02\/DIN001-STM32F091RC-ISO485-IO-_Encl_PCB-_640x286-500x223.jpg 500w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/a><p id=\"caption-attachment-672\" class=\"wp-caption-text\">DIN001 Distributed Controller &#8211; BMS \/ HVAC \/ IO &#8211; Fan Interface<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Applications Distributed Control Systems RS485 Networked Systems HVAC On Board 2 x ADM2687 isolated RS485 transcievers 1 x non isolated RS485 port 4 Analog Inputs Opto Mosfet Output Isolated Analog Control Port for Fans Local Power Management (for a 48V &hellip; <a href=\"http:\/\/furzy.com\/mikesblog\/2017\/12\/17\/din001-stm32f091rc-iso485-io-new-controller-product\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2}},"categories":[9],"tags":[38,78,13,16,17,43,42,80],"class_list":["post-515","post","type-post","status-publish","format-standard","hentry","category-development","tag-arm-cortex-m0","tag-data-acquisition","tag-electronics-design","tag-industrial-control","tag-industrial-monitoring","tag-io-end-point","tag-iot","tag-stm32f091rc"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p7DDag-8j","_links":{"self":[{"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/posts\/515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/comments?post=515"}],"version-history":[{"count":12,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/posts\/515\/revisions"}],"predecessor-version":[{"id":776,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/posts\/515\/revisions\/776"}],"wp:attachment":[{"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/media?parent=515"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/categories?post=515"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/furzy.com\/mikesblog\/wp-json\/wp\/v2\/tags?post=515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}